Confirm application

【Grid-connected Inverter】 300W 400W 500W CE/ROHS Micro inverter

Serial Code : MAYSUN300-500W Product Code : MAYSUN300-500W Product Info :

Maximum power point tracking (MPPT) effectively tracks and locks onto the solar panel's maximum output power.

Once the inverter tracks the solar panel's MPPT, it automatically locks onto a stable power output.

Standard MC4 input port for simple and safe connection.

Integrated AC output port.

model MaySun300/400/500
Photovoltaic input (DC, PV)
Number of MC4 input connectors Group 1
MPPT Maximum Power Point Tracking Voltage Range 28V-55V
Operating voltage range 20V-60V
Maximum branch input voltage 60V
Start-up voltage 20V
Maximum DC input current 10A/13.33A/16.66A
AC output
Single-phase power grid type 120V or 230V
Rated output power 295W/380W/480W
Maximum output power 300W/400W /500W
Rated AC current 120V:2.5A/3.16A/4A 230V:1.3A/1.65A/2.09A
Rated AC voltage 120VAC / 230VAC
Output voltage range @120VAC : 80V-160V / @230VAC : 180V-280V
Rated AC frequency 50Hz / 60Hz
Output frequency range @50Hz : 47.5Hz-52.5Hz / @60Hz : 57.5Hz-62.5Hz
Output power factor >0.99
Total Harmonic Distortion of Output Current THD <5%
efficiency
Maximum conversion efficiency 95%
CEC weighted efficiency @120VAC : 92.5% / @230VAC : 93.5%
MPPT tracking efficiency 99.9%
Nighttime losses <700mW
Mechanical data
Operating ambient temperature -40°C to +65°C
Storage ambient temperature -40°C to +85°C
Machine dimensions (length x width x height) 18cm x 20.5cm x 4cm
net weight 0.83kg
Maximum current of AC cable 20A
Protection level IP65
Cooling method Natural cooling
Other features
Communication methods WIFI wireless communication (cloud monitoring)
Isolation characteristics High-frequency transformer isolation
Integrated grounding The PE terminal in the AC cable is the equipment's grounding wire; there are no other grounding ports.
Protection methods Islanding protection, voltage protection, frequency protection, temperature protection, current protection, etc.
Design Standards CE, etc.

New Chinese Micro Reversal Manual.pdf Download
MAYSUN Series Inverter CE Certification.pdf Download
MAYSUN Series Inverter RoHS Certification.pdf Download
MAYSUN series inverters REACH certification.pdf Download

Tell us the questions you need to consult

You can also contact us directly in the following ways: visit, telephone, email